Filter Integrity Tester

FIT-3.0/FIT-4.0

FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify the sterilizing filter in the FDA, the State Pharmacopoeia and GMP specification requirements.

More details

Product info

FIT Serials Integrity Tester are designed for testing integrity of filters and filter systems . The test meet to verify the sterilizing filter in the FDA, the State Pharmacopoeia and GMP specification requirements. The FIT-4.0 Integrity Tester is compact, handy to use, and fully automated integrity test instrument, which performs bubble point, diffusion flow, enhanced bubble point, and water-based test for hydrophobic filters. The first domestic launch of integrity test for water-based test for hydrophobic filters to meet different customer needs.

Main features:

  • The scientific electronic signature and classification to distinguish the responsibility easily, and to prevent false operation.
  • Display of test data and curves in real time, monitoring the whole process of testing.
  • Provides automatic printing set function, the user can operate more simple and convenient.
  • Water Based test (WH) for Hydrophobic Filter: using purified water as test liquid instead of IPA and Ethanol, thus it can avoid trace quantity of ethanol or IPA contamination when testing filters.
  • The instrument can store 500 history record and curve.
  • Advanced "water intrusion method” has solved the disadvantage that the hydrophobic filter can only be tested immersed in organic solvent .
  • Advanced automatic control system, no need of manual adjusting pressure, to ensure the accuracy and precision.
  • Real-time displaying test data and curve, monitoring the whole testing process.
  • Dual-core operation, with PC software.
  • Covers all of the functions of foreign similar instruments.
  • More perfect user extension management, users can change the password according to need.
  • Add the automatic protection function for tested filters, to avoid doing harm to the filter because of overvoltage testing.
  • Provide automatic printing setting, and make the operation more easy and convenient.
  • 5.7 " backlight digital LCD, display clearly.
  • Testing the Diffusion flux of the disc membrane is of important significance for judging the characteristics of the membrane.

Specifications:


Model

FIT-4.0

FIT-3.0

power

170-240VAC,50/60Hz, 110W

170-240VAC,50/60Hz, 110W

Maximum working pressure

8000mbar

8000mbar

Minimum working pressure

100mbar

100mbar

Dimensions (L*D*H)mm

240X380X285

400X380X235

Test pressure

500-6900 mbar

500-6900 mbar

Test accuracy

Upstream volume test: ± 4%;
bubble point: ± 50 mbar;
diffusion flow: ± 4%;
water immersion: ± 0.1 ml/min

Upstream volume test: ± 4%;
bubble point: ± 50 mbar;
diffusion flow: ± 4%;

Working condition

Temperature: 5℃±35℃;
Moisture: 10~80%

Temperature: 5℃±35℃;
Moisture: 10~80%

Test time

Upstream volume test : 5min±2min;
Quick D test: 10min±2min
Base BP test: 15min±2min
Enhanced test: 20min±2min
water immersion: +5min±2min

Upstream volume test : 5min±2min;
Quick D test: 10min±2min
Base BP test: 15min±2min
Enhanced test: 20min±2min

Checklist print

Input parameters & output data and result

Input parameters & output data and result

History record

500 test records + graphic curves

500 test records + graphic curves

LCD

5.7″ ; TFT, monocular

5.7″ ; TFT, monocular

Series I/O type

RS232

RS232

Language of menu

English

English

 

5 other products in the same category: